Alor panelling combines curated, authentic timber finishes with engineered performance designed for New Zealand and Australian lifestyles. Prefinished for convenience and crafted to the highest standards, every plank undergoes real-world testing and rigorous quality control to deliver industry-leading durability, stability and long-term peace of mind.
Forté's Alor Timber Wall & Ceiling System is designed for direct-fix and battened installation across a range of approved substrates, including plasterboard, timber framing/battens, and concrete or masonry walls. Each substrate type carries its own specific requirements around fixing method, moisture content, and surface preparation, all of which are addressed in full within the Design Guide.
Key specification points:
Approved substrates: plasterboard, timber framing/battens, concrete/masonry walls
Not recommended for wet areas or direct splash zones; may be considered in adjacent dry zones within kitchens, bathrooms and laundries with appropriate ventilation and detailing
Must be separated from fuel-burning appliances, flues, and chimneys per NZBC Section C AS/1
Full scope, limitations and technical detailing are set out in our Alor Walls & Ceiling Panelling Design Guide.
Download our Alor Walls & Ceiling Panelling Design GuideSpecifications
Our European Oak and American Walnut panelling offers a refined Prime grade across eight colourways, to suit any space or style. Every plank is prefinished with a durable UV-cured lacquer and a locking Flexiclick joint profile for consistent, long-lasting performance.
Specifications | Forté Collections |
|---|---|
Species | European Oak / American Walnut |
Grade | Prime |
Thickness | 10mm |
Width | 150mm |
Length | 2700mm |
Veneer | 0.6mm European Oak / American Walnut |
Construction | 3-Layer, HDF Core |
Surface Finish Type | Prefinished UV Cured Lacquer |
Surface Texture | Lightly Brushed |
Surface Sheen | Extra Matte |
Joint Profile | Flexiclick |
The Alor Wall & Ceiling Panelling Design Guide is the reference point for specifying and detailing Forté's Alor collection with confidence. It covers the full system — from approved substrates and fixing systems through to wet area detailing, climate control, and trims and transitions — giving specifiers the technical grounding needed to design a compliant, long-performing wall or ceiling from the substrate up.
Detailed technical drawings and fixing specifications accompany each substrate and condition, providing the construction detail required to translate the guide directly into working documentation.
Compliance is demonstrated against the relevant NZBC clauses with each addressed in full in the Design Guide's compliance table. Every specification detail in the guide — from substrate build-ups to trims, transitions and corner profiles — is drawn from tested, documented practice, ensuring the system performs as intended across the full range of design conditions it's built for.
Download our Alor Walls & Ceiling System Design Guide View on Productspec View on Smartspec View on Programma View on EbossCompliance & Testing
Forté's Alor Timber Wall & Ceiling System satisfies the BPIR Declaration requirements under the Building (Building Product Information Requirements) Regulations 2022, and demonstrates compliance with the relevant clauses of the New Zealand Building Code as set out in the Design Guide. This gives specifiers a documented, reliable compliance pathway from concept through to Building Consent.
NZ Building Code Clause | Compliance Pathway | Demonstrated by |
|---|---|---|
B1 STRUCTURE B1.3.1, B1.3.2, B1.3.3(j), B1.3.4 | Assessed per B1/VM1 principles | Non-structural internal lining, stable under self-weight and service loads, securely fixed to suitable substrate, accommodates building movement without detachment or distortion |
B2 DURABILITY B2.1.1.1C | Manufacturer warranty & durability assessment | 5-year service life for internal elements (NZBC B2/AS1); backed by 7-year manufacturer warranty on material and manufacturing performance |
C1 LIMITING HEAT TRANSFER C1.3.2 | Assessed per C/VM1 | Not intended for surfaces exceeding 70°C; requires appropriate clearance and ventilation near heat-producing appliances |
C2 PREVENTION OF FIRE OCCURRING C2.2 | Tested per C/VM2, Table A1, Appendix A | Group 3 fire classification (Group 1-S achievable with FR core or intumescent coating system) |
C3 FIRE AFFECTING AREAS BEYOND THE FIRE SOURCE C3.4(a) | Assessed per C/AS2 | Surface finish performance suitable for relevant building use and location, confirmed by designer/specifier |
E3 INTERNAL MOISTURE E3.3.4, E3.3.5, E3.3.6 | Assessed per NZBC E3/AS1 | Suitable for dry internal applications only; not recommended for wet areas or humidity exceeding 70% |
F2 HAZARDOUS BUILDING MATERIALS (1st Edition) F2.3.1 | Tested to AS/NZS 2098.11 | Super E0 formaldehyde emission rating |
Forté is committed to reducing its impact on the environment across every stage of production, from responsible forest sourcing through to the long-term performance of the products themselves. This commitment is backed by third-party certification: Forté holds an FSC Promotional Licence and FSC Chain of Custody Certification (SGSHK-COC-510037), alongside PEFC Chain of Custody Certification (SGSCH-PEFC-COC-510014), ensuring products are sourced from forests managed to protect biodiversity, support local communities, and uphold fair labour practices.
Alor panelling itself carries genuine environmental advantages over solid timber linings. Because only a thin veneer layer is solid hardwood, Alor uses just 1/16th of the natural timber resource required for solid timber interior linings of the same dimensions — making it both a more sustainable and more cost-effective way of achieving a prime-grade surface.
Every detail, one point of contact. Speak to a Forté specification consultant and get the technical support, documentation, and product knowledge you need to specify our Alor walls & ceiling panelling with confidence — all from one place.
ENQUIREWhat substrates can this panelling go over?
Gib/plasterboard (level and securely fixed), timber framing or battens (useful over uneven surfaces, with moisture content kept below 12 percent), and concrete or masonry (with approved adhesives and battens, surface dry and level). Other substrates need a case-by-case check with Forté Technical Support.
How is it fixed?
Glue-down with secret pinning is the recommended method for both ranges. We recommend Mapei Ultrabond S997 1K Adhesive with a 16-gauge finishing brad (50mm over gib, 45mm over other substrates). Alor's locking joint profile also allows direct fixing to framing without gib.
Can it go over an uneven wall or ceiling?
Yes — shims, battens or packed-out plasterboard can bring the surface flush before installation. Minor irregularities can be handled with filler, levelling compound or adhesive adjustments. Always check with your installer for site-specific advice.
Will the timber move or change with the seasons?
Yes — timber is hygroscopic, meaning it naturally absorbs and releases moisture as conditions change. Keeping ambient temperature between 16-27°C and relative humidity between 40-60 percent minimises movement and hairline cracking. Expansion gaps and transition details in the design guide are built around this natural movement.
How does sunlight affect the panelling?
Direct, unfiltered UV exposure can noticeably change timber's colour within one to three months — darkening, lightening or yellowing. Surface temperatures above 45°C in direct sun increase the risk of cupping, warping and coating deterioration. Even 99.9 percent UV-blocking glass or film still lets through visible light and heat that can cause gradual colour change, so we recommend layering architectural glass or window film with curtains or blinds in high-sun rooms.
What's the warranty?
The engineered overlay system carries a 25-year structural warranty and a 7-year finish warranty. Alor carries a 7-year manufacturer warranty covering material and manufacturing performance under specified conditions.
Is it safe indoors — any formaldehyde concerns?
Both ranges achieve a Super E0 formaldehyde emission rating. As with any timber product, a dust mask is recommended when cutting.
How do you finish the edge where panelling meets gib, tile, joinery or another material?
Forté offers a range of transition solutions for each junction: metal angle trims and flat bars (silver, black, champagne, light and dark bronze anodised aluminium, plus brass and waxed steel organic finishes) for timber-to-carpet and timber-to-timber junctions; joinery angle trim colour-matched or powder-coated to suit; and colour-matched caulking for junctions with skirting, cabinetry or joinery. We don't sell tile trims — the Tilers Mate L-Angle Tile Trim is our general recommendation, sized to the tile thickness.
Can panelling sit flush or proud of the wall?
Both — flush for a seamless, continuous look, or proud to create shadow lines and design emphasis. The choice affects which trim detail is used at terminations and mid-wall junctions.
Can I use timber panelling in a bathroom?
It depends which range and how it's specified. The engineered overlay system has a documented Alternative Solution that complies with ISO 4760 for imperviousness, but it's limited to splash zones only — not continuous standing water or direct wet-floor showers — and must follow Forté's full wet-area installation system (waterproofing membrane, sealing, adhesives and edge detailing as specified). Alor is not recommended for wet areas or direct splash zones, including showers and bath surrounds, even with a wet-area installation system; it can be considered in dry-zone areas of a kitchen, bathroom or laundry that don't get direct water contact.
What humidity level should the room be kept at?
40-60 percent relative humidity is ideal for both ranges. Below 35 percent or above 70 percent increases the risk of product movement and hairline cracks. In wet-area installations, ventilation should keep humidity below 60 percent, with mechanical extraction where needed.